FINITE ELEMENT ANALYSIS OF A TI6AL4V (ELI) MEDICAL IMPLANT PRODUCED THROUGH ADDITIVE MANUFACTURING

dc.contributor.authorMONAHENG, LEHLOHONOLO FRANCIS
dc.date.accessioned2018-04-20T08:43:49Z
dc.date.available2018-04-20T08:43:49Z
dc.date.issued2017
dc.descriptionPublished Thesisen_US
dc.description.abstractMedical implants created by Ti6Al4V (ELI) through Additive Manufacturing (AM) processes have a very positive impact on the quality of life of patients who have undergone skeletal reconstructive surgery. The effectiveness of medical implant design for AM processes would be significantly improved if finite element analysis (FEA) could be established as an accepted design tool. This study is aimed at validating FEA as a tool for predicting the strain distribution in a Ti6Al4V (ELI) medical implant produced through a selective laser melting (SLM) process by comparing the FEA results with strain gauge measurements. The approach followed was to demonstrate the correlation between an FEA model and strain gauge measurements performed on a human mandibular implant. For the design of the mandibular implant the geometrical data of an adult human mandible obtained from a computer tomography (CT) scan was transferred to a computer-aided design (CAD) software package. A CAD model based on this data, which was suitable for experimental validation, was used for FEA when subjected to typical static mastication load condition. Through this FEA simulation the distribution of strain in the implant under basic functional condition was determined. Using the same CAD model, an implant was manufactured through SLM and strain gauges were mounted on the implant at locations corresponding to the areas of significant strain as determined on the FEA model. The results obtained from both FEA and strain gauge measurements were compared and a correlation within a deviation of less than 10% for most of the measurements was obtained. Requirements for achieving this level of correlation were determined. It was concluded that FEA is indeed a powerful tool for improving the effectiveness of design for AM of medical implants.en_US
dc.format.extent15 429 131 bytes, 1 file
dc.format.mimetypeApplication/PDF
dc.identifier.urihttp://hdl.handle.net/11462/1333
dc.language.isoen_USen_US
dc.publisherBloemfontein: Central University of Technology, Free Stateen_US
dc.rights.holderCentral University of Technology, Free State
dc.subjectFinite element analysisen_US
dc.subjectStrain gauge measurementsen_US
dc.subjectAdditive manufacturingen_US
dc.subjectMedical implantsen_US
dc.subjectTi6Al4V (ELI) materialen_US
dc.titleFINITE ELEMENT ANALYSIS OF A TI6AL4V (ELI) MEDICAL IMPLANT PRODUCED THROUGH ADDITIVE MANUFACTURINGen_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Monaheng, Lehlohonolo Francis.pdf
Size:
14.71 MB
Format:
Adobe Portable Document Format
Description:
Thesis

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: